| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| There is an elevation of privilege breakout vulnerability in the Windows EXE installer in Scooter Beyond Compare 4.2.0 through 4.4.2 before 4.4.3. Affected versions allow a logged-in user to run applications with elevated privileges via the Clipboard Compare tray app after installation. |
| Improper access control in some Intel(R) Aptio* V UEFI Firmware Integrator Tools before version iDmiEdit-Linux-5.27.06.0017 may allow a privileged user to potentially enable escalation of privilege via local access. |
| Improper access control in some Intel(R) Aptio* V UEFI Firmware Integrator Tools before version iDmi Windows 5.27.03.0003 may allow a privileged user to potentially enable escalation of privilege via local access. |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable and could only be recovered by power cycling the device. |
| Airspan AirVelocity 1500 software prior to version 15.18.00.2511 had NET-SNMP-EXTEND-MIB enabled on its snmpd service, enabling an attacker with SNMP write abilities to execute commands as root on the eNodeB. This issue may affect other AirVelocity and AirSpeed models. |
| Clinic's Patient Management System v1.0 has arbitrary code execution via url: ip/pms/users.php. |
| In Airspan AirSpot 5410 version 0.3.4.1-4 and under there exists a Hidden system command web page. After performing a reverse engineering of the firmware, it was discovered that a hidden page not listed in the administration management interface allows a user to execute Linux commands on the device with root privileges. An authenticated malicious threat actor can use this page to fully compromise the device. |
| Kiosk breakout (without quit password) in Safe Exam Browser (Windows) <3.4.0, which allows an attacker to achieve code execution via the browsers' print dialog. |
| The Linux kernel before 5.18.13 lacks a certain clear operation for the block starting symbol (.bss). This allows Xen PV guest OS users to cause a denial of service or gain privileges. |
| An issue was discovered in Blue Prism Enterprise 6.0 through 7.01. In a misconfigured environment that exposes the Blue Prism Application server, it is possible for an authenticated user to reverse engineer the Blue Prism software and circumvent access controls for the UpdateOfflineHelpData administrative function. Abusing this function will allow any Blue Prism user to change the offline help URL to one of their choice, opening the possibility of spoofing the help page or executing a local file. |
| An issue was discovered in Blue Prism Enterprise 6.0 through 7.01. In a misconfigured environment that exposes the Blue Prism Application server, it is possible for an authenticated user to reverse engineer the Blue Prism software and circumvent access controls for the getChartData administrative function. Using a low/no privilege Blue Prism user account, the attacker can alter the server's settings by abusing the getChartData method, allowing the Blue Prism server to execute any MSSQL stored procedure by name. |
| An issue was discovered in Blue Prism Enterprise 6.0 through 7.01. In a misconfigured environment that exposes the Blue Prism Application server, it is possible for an authenticated user to reverse engineer the Blue Prism software and circumvent access controls for the SetProcessAttributes administrative function. Abusing this function will allow any Blue Prism user to publish, unpublish, or retire processes. Using this function, any logged-in user can change the status of a process, an action allowed only intended for users with the Edit Process permission. |
| An issue was discovered in Blue Prism Enterprise 6.0 through 7.01. In a misconfigured environment that exposes the Blue Prism Application server, it is possible for an authenticated user to reverse engineer the Blue Prism software and circumvent access controls for an administrative function. If credential access is configured to be accessible by a machine or the runtime resource security group, using further reverse engineering, an attacker can spoof a known machine and request known encrypted credentials to decrypt later. |
| An issue was discovered in Blue Prism Enterprise 6.0 through 7.01. In a misconfigured environment that exposes the Blue Prism Application server, it is possible for an authenticated user to reverse engineer the Blue Prism software and circumvent access controls for the setValidationInfo administrative function. Removing the validation applied to newly designed processes increases the chance of successfully hiding malicious code that could be executed in a production environment. |
| An issue was discovered in Blue Prism Enterprise 6.0 through 7.01. In a misconfigured environment that exposes the Blue Prism Application server, it is possible for an authenticated user to reverse engineer the Blue Prism software and circumvent access controls for unintended functionality. An attacker can abuse the CreateProcessAutosave() method to inject their own functionality into a development process. If (upon a warning) a user decides to recover unsaved work by using the last saved version, the malicious code could enter the workflow. Should the process action stages not be fully reviewed before publishing, this could result in the malicious code being run in a production environment. |
| In grails-databinding in Grails before 3.3.15, 4.x before 4.1.1, 5.x before 5.1.9, and 5.2.x before 5.2.1 (at least when certain Java 8 configurations are used), data binding allows a remote attacker to execute code by gaining access to the class loader. |
| Cambium Enterprise Wi-Fi System Software before 6.4.2 does not sanitize the ping host argument in device-agent. |
| This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition 8.1.15 (b2022030114). User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the processing of ZIP files. Crafted data in a ZIP file can cause the application to execute arbitrary Python scripts. The user interface fails to provide sufficient indication of the hazard. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-16949. |
| Nautilus treadmills T616 S/N 100672PRO21140001 through 100672PRO21171980 and T618 S/N 100647PRO21130111 through 100647PRO21183960 with software before 2022-06-09 allow physically proximate attackers to cause a denial of service (fall) by connecting the power cord to a 120V circuit (which may lead to self-starting at an inopportune time). |
| IBM PowerVM VIOS 3.1 could allow a remote attacker to tamper with system configuration or cause a denial of service. IBM X-Force ID: 230956. |