| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An attacker with local access to the medical office computer can
access restricted functions of the Elefant Service tool by using a
hard-coded "Hotline" password in the Elefant service binary, which is shipped with the software. |
| Ever Traduora 0.20.0 and below is vulnerable to Privilege Escalation due to the use of a hard-coded JWT signing key. |
| MinMax CMS from MinMax Digital Technology contains a hidden administrator account with a fixed password that cannot be removed or disabled from the management interface. Remote attackers who obtain this account can bypass IP access control restrictions and log in to the backend system without being recorded in the system logs. |
| The SunPower PVS6's BluetoothLE interface is vulnerable due to its use of hardcoded encryption parameters and publicly accessible protocol details. An attacker within Bluetooth range could exploit this vulnerability to gain full access to the device's servicing interface. This access allows the attacker to perform actions such as firmware replacement, disabling power production, modifying grid settings, creating SSH tunnels, altering firewall settings, and manipulating connected devices. |
| A vulnerability has been found in E-Lins H685, H685f, H700, H720, H750, H820, H820Q, H820Q0 and H900 up to 3.2 and classified as critical. This vulnerability affects unknown code of the component OEM Backend. The manipulation leads to hard-coded credentials. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. It is recommended to change the configuration settings. The vendor was contacted early about this disclosure but did not respond in any way. |
| Netis E1+ version 1.2.32533 contains a hardcoded root account vulnerability that allows unauthenticated attackers to access the device with predefined credentials. Attackers can leverage the embedded root account with a crackable password to gain full administrative access to the network device. |
| Quantum StorNext Web GUI API before 7.2.4 grants access to internal StorNext configuration and unauthorized modification of some software configuration parameters via undocumented user credentials. This affects StorNext RYO before 7.2.4, StorNext Xcellis Workflow Director before 7.2.4, and ActiveScale Cold Storage. |
| In Optigo Networks ONS NC600 versions 4.2.1-084 through 4.7.2-330, an attacker could connect with the device's ssh server and utilize the system's components to perform OS command executions. |
| The wsc server uses a hard-coded certificate to check the authenticity of SOAP messages. An unauthenticated remote attacker can extract private keys from the Software of the affected devices. |
| A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system.
Other related CVE's are CVE-2025-14095 & CVE-2025-14097.
Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.
Required Configuration for Exposure:
Attacker requires physical access to the analyzer.
Temporary work Around:
Only authorized people can physically access the analyzer.
Permanent solution:
Local Radiometer representatives will contact all affected customers to discuss a permanent solution.
Exploit Status:
Researchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication. |
| Use of hard-coded, the same among all vulnerable installations SQLite credentials vulnerability in SIGNUM-NET FARA allows to read and manipulate local-stored database.This issue affects FARA: through 5.0.80.34. |
| Use of Hard-coded Credentials vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5 and newer versions |
| Array Networks vAPV (version 8.3.2.17) and vxAG (version 9.2.0.34) appliances are affected by a privilege escalation vulnerability caused by a combination of hardcoded SSH credentials (or SSH private key) and insecure permissions on a startup script. The devices ship with a default SSH login or a hardcoded DSA private key, allowing an attacker to authenticate remotely with limited privileges.
Once authenticated, an attacker can overwrite the world-writable /ca/bin/monitor.sh script with arbitrary commands. Since this script is executed with elevated privileges through the backend binary, enabling the debug monitor via backend -c "debug monitor on" triggers execution of the attacker's payload as root. This allows full system compromise. |
| The WP2Speed Faster – Optimize PageSpeed Insights Score 90-100 plugin for WordPress is vulnerable to unauthorized access in all versions up to, and including, 1.0.1. This is due to the use of hardcoded credentials to authenticate all the incoming API requests. This makes it possible for unauthenticated attackers to overwrite CSS, update the trial settings, purge the cache, and find attachments. |
| DCIM dcTrack platforms utilize default and hard-coded credentials for access. An attacker could use these credentials to administer the database, escalate privileges on the platform or execute system commands on the host. |
| Neye3C v4.5.2.0 was discovered to contain a hardcoded encryption key in the firmware update mechanism. |
| Vulnerabilities* in ActADUR local server product, developed and maintained by ProTNS, allows Remote Code Inclusion on host systems.
* vulnerabilities:
*
Improper Neutralization of Special Elements used in a Command ('Command Injection')
* Use of Hard-coded Credentials
* Improper Authentication
* Binding to an Unrestricted IP Address
The vulnerability has been rated as critical.This issue affects ActADUR: from v2.0.1.9 before v2.0.2.0., hence updating to version v2.0.2.0. or above is required. |
| SQL Anywhere Monitor (Non-GUI) baked credentials into the code,exposing the resources or functionality to unintended users and providing attackers with the possibility of arbitrary code execution.This could cause high impact on confidentiality integrity and availability of the system. |
| Iridium Certus 700 version 1.0.1 has an embedded credentials vulnerability in the code. This vulnerability allows a local user to retrieve the SSH hash string. |
| hippo4j 1.0.0 to 1.5.0, uses a hard-coded secret key in its JWT (JSON Web Token) creation. This allows attackers with access to the source code or compiled binary to forge valid access tokens and impersonate any user, including privileged ones such as "admin". The vulnerability poses a critical security risk in systems where authentication and authorization rely on the integrity of JWTs. |