| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Shenzhen Tuoshi NR500-EA RG500UEAABxCOMSLICv3.4.2731.16.43 devices enable the SSH service by default. There is a hidden hard-coded root account that cannot be disabled in the GUI. |
| ui/pref/ProxyPrefView.java in weasis-core in Weasis 4.5.1 has a hardcoded key for symmetric encryption of proxy credentials. |
| There are several hidden accounts. Some of them are intended for maintenance engineers, and with the knowledge of their passwords (e.g., by examining the coredump), these accounts can be used to re-configure the device. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References]. |
| A hardcoded privileged ID within Lumisxp v15.0.x to v16.1.x allows attackers to bypass authentication and access internal pages and other sensitive information. |
| IBM Sterling Connect:Direct for UNIX Container 6.3.0.0 through 6.3.0.6 Interim Fix 016, and 6.4.0.0 through 6.4.0.3 Interim Fix 019 IBM® Sterling Connect:Direct for UNIX contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. |
| Multiple hardcoded credentials have been identified, which are allowed to sign-in to the exos 9300 datapoint server running on port 1004 and 1005. This server is used for relaying status information from and to the Access Managers. This information, among other things, is used to graphically visualize open doors and alerts. However, controlling the Access Managers via this interface is also possible.
To send and receive status information, authentication is necessary. The Kaba exos 9300 application contains hard-coded credentials for four different users, which are allowed to login to the datapoint server and receive as well as send information, including commands to open arbitrary doors. |
| We observed that Intellispace Portal binaries doesn’t have any protection mechanisms to prevent reverse engineering. Specifically, the app’s code is not obfuscated, and no measures are in place to protect against decompilation, disassembly, or debugging. As a result, attackers can reverse-engineer the application to gain insights into its internal workings, which can potentially lead to the discovery of sensitive information, business logic flaws, and other vulnerabilities.
Utilizing this flaw, the attacker was able to identify the Hardcoded credentials from PortalUsersDatabase.dll, which contains .NET remoting definition. Inside the namespace PortalUsersDatabase, the class Users contains the functions CreateAdmin and CreateService that are used to initialize accounts in the Portal service. Both CreateAdmin and CreateService functions contain a hardcoded encrypted password along with its respective salt that are set with the function SetInitialPasswordAndSalt.
This issue affects IntelliSpace Portal: 12 and prior; Advanced Visualization Workspace: 15. |
| An issue was discovered on ROADCAM X3 devices. It has a uniform default credential set that cannot be modified by users, making it easy for attackers to gain unauthorized access to multiple devices. |
| It appears that some hardcoded keys are used for authentication to internal API. Knowing these private keys may allow attackers to bypass authentication and reach administrative interfaces. As for the affected products/models/versions, see the reference URL. |
| An authentication bypass vulnerability in the /web/um_open_telnet.cgi endpoint in Nexxt Solutions NCM-X1800 Mesh Router firmware UV1.2.7 and below, allowing an attacker to remotely enable the Telnet service without authentication, bypassing security controls. The Telnet server is then accessible with hard-coded credentials, allowing attackers to gain administrative shell access and execute arbitrary commands on the device. |
| Hard-coded credentials were included as part of the application binary.
These credentials served as part of the application authentication flow
and communication with the mobile application. An attacker could access
unauthorized information. |
| An unauthenticated remote attacker can use hard-coded credentials to gain full administration privileges on the affected product. |
| Use of Hard-coded Credentials vulnerability in GE Vernova EnerVista UR Setup allows Privilege Escalation. The local user database is encrypted using an hardcoded password retrievable by an attacker analyzing the application code. |
| NixOS's Onlyoffice is a software suite that offers online and offline tools for document editing, collaboration, and management. In versions from 22.11 to before 25.05 and versions before Unstable 25.11, a hard-coded secret was used in the NixOS module for the OnlyOffice document server to protect its file cache. An attacker with knowledge of an existing revision ID could use this secret to obtain a document. In practice, an arbitrary revision ID should be hard to obtain. The primary impact is likely the access to known documents from users with expired access. This issue was resolved in NixOS unstable version 25.11 and version 25.05. |
| Project AI is a platform designed to create AI agents. Prior to the pre-beta version, a hardcoded API key was present in the source code. This issue has been patched in the pre-beta version. |
| A vulnerability classified as critical was found in NuCom NC-WR744G 8.5.5 Build 20200530.307. This vulnerability affects unknown code of the component Console Application. The manipulation of the argument CMCCAdmin/useradmin/CUAdmin leads to hard-coded credentials. The attack can be initiated remotely. The vendor was contacted early about this disclosure but did not respond in any way. |
| An issue was discovered on the Audi Universal Traffic Recorder 2.88. It has Susceptibility to denial of service. It uses the same default credentials for all devices and does not implement proper multi-device authentication, allowing attackers to deny the owner access by occupying the only available connection. The SSID remains broadcast at all times, increasing exposure to potential attacks. |
| Certain models of D-Link wireless routers contain an undisclosed factory testing backdoor. Unauthenticated attackers on the local area network can force the device to enable Telnet service by accessing a specific URL and can log in by using the administrator credentials obtained from analyzing the firmware. |
| All the Toshiba printers contain a shell script using the same hardcoded key to encrypt logs. An attacker can decrypt the encrypted files using the hardcoded key. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point.
https://www.toshibatec.com/contacts/products/
As for the affected products/models/versions, see the reference URL. |
| All the Toshiba printers contain a shell script using the same hardcoded key to encrypt logs. An attacker can decrypt the encrypted files using the hardcoded key. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point.
https://www.toshibatec.com/contacts/products/
As for the affected products/models/versions, see the reference URL. |