| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected products use a numeric password with a small maximum character size for the password. |
| The hesiod_init function in lib/hesiod.c in Hesiod 3.2.1 compares EUID with UID to determine whether to use configurations from environment variables, which allows local users to gain privileges via the (1) HESIOD_CONFIG or (2) HES_DOMAIN environment variable and leveraging certain SUID/SGUID binary. |
| A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands. |
| A Plaintext Storage of a Password issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application's configuration file contains parameters that represent passwords in plaintext. |
| A Password in Configuration File issue was discovered in Dahua DH-IPC-HDBW23A0RN-ZS, DH-IPC-HDBW13A0SN, DH-IPC-HDW1XXX, DH-IPC-HDW2XXX, DH-IPC-HDW4XXX, DH-IPC-HFW1XXX, DH-IPC-HFW2XXX, DH-IPC-HFW4XXX, DH-SD6CXX, DH-NVR1XXX, DH-HCVR4XXX, DH-HCVR5XXX, DHI-HCVR51A04HE-S3, DHI-HCVR51A08HE-S3, and DHI-HCVR58A32S-S2 devices. The password in configuration file vulnerability was identified, which could lead to a malicious user assuming the identity of a privileged user and gaining access to sensitive information. |
| In Kibana X-Pack security versions prior to 5.4.3 if a Kibana user opens a crafted Kibana URL the result could be a redirect to an improperly initialized Kibana login screen. If the user enters credentials on this screen, the credentials will appear in the URL bar. The credentials could then be viewed by untrusted parties or logged into the Kibana access logs. |
| The Reporting feature in X-Pack in versions prior to 5.5.2 and standalone Reporting plugin versions versions prior to 2.4.6 had an impersonation vulnerability. A user with the reporting_user role could execute a report with the permissions of another reporting user, possibly gaining access to sensitive data. |
| An issue was discovered on Mimosa Client Radios before 2.2.3. In the device's web interface, there is a page that allows an attacker to use an unsanitized GET parameter to download files from the device as the root user. The attacker can download any file from the device's filesystem. This can be used to view unsalted, MD5-hashed administrator passwords, which can then be cracked, giving the attacker full admin access to the device's web interface. This vulnerability can also be used to view the plaintext pre-shared key (PSK) for encrypted wireless connections, or to view the device's serial number (which allows an attacker to factory reset the device). |
| Csrf.cs in NancyFX Nancy before 1.4.4 and 2.x before 2.0-dangermouse has Remote Code Execution via Deserialization of JSON data in a CSRF Cookie. |
| Remote Code Execution is possible in Code42 CrashPlan 5.4.x via the org.apache.commons.ssl.rmi.DateRMI Java class, because (upon instantiation) it creates an RMI server that listens on a TCP port and deserializes objects sent by TCP clients. |
| Vulnerability in the MySQL Connectors component of Oracle MySQL (subcomponent: Connector/J). Supported versions that are affected are 5.1.40 and earlier. Difficult to exploit vulnerability allows low privileged attacker with network access via multiple protocols to compromise MySQL Connectors. While the vulnerability is in MySQL Connectors, attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of MySQL Connectors. CVSS 3.0 Base Score 8.5 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H). |
| The Hotspot component in OpenJDK8 as packaged in Red Hat Enterprise Linux 6 and 7 allows local users to write to arbitrary files via a symlink attack. |
| IBM Websphere MQ JMS 7.0.1, 7.1, 7.5, 8.0, and 9.0 client provides classes that deserialize objects from untrusted sources which could allow a malicious user to execute arbitrary Java code by adding vulnerable classes to the classpath. IBM Reference #: 1983457. |
| The _write_config function in trove/guestagent/datastore/experimental/mongodb/service.py, reset_configuration function in trove/guestagent/datastore/experimental/postgresql/service/config.py, write_config function in trove/guestagent/datastore/experimental/redis/service.py, _write_mycnf function in trove/guestagent/datastore/mysql/service.py, InnoBackupEx::_run_prepare function in trove/guestagent/strategies/restore/mysql_impl.py, InnoBackupEx::cmd function in trove/guestagent/strategies/backup/mysql_impl.py, MySQLDump::cmd in trove/guestagent/strategies/backup/mysql_impl.py, InnoBackupExIncremental::cmd function in trove/guestagent/strategies/backup/mysql_impl.py, _get_actual_db_status function in trove/guestagent/datastore/experimental/cassandra/system.py and trove/guestagent/datastore/experimental/cassandra/service.py, and multiple class CbBackup methods in trove/guestagent/strategies/backup/experimental/couchbase_impl.py in Openstack DBaaS (aka Trove) as packaged in Openstack before 2015.1.0 (aka Kilo) allows local users to write to configuration files via a symlink attack on a temporary file. |
| The IPTables-Parse module before 1.6 for Perl allows local users to write to arbitrary files owned by the current user. |
| sosreport in SoS 3.x allows local users to obtain sensitive information from sosreport files or gain privileges via a symlink attack on an archive file in a temporary directory, as demonstrated by sosreport-$hostname-$date.tar in /tmp/sosreport-$hostname-$date. |
| An issue was discovered in SMA Solar Technology products. All inverters have a very weak password policy for the user and installer password. No complexity requirements or length requirements are set. Also, strong passwords are impossible due to a maximum of 12 characters and a limited set of characters. NOTE: the vendor reports that the 12-character limit provides "a very high security standard." Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected |
| The rend_service_intro_established function in or/rendservice.c in Tor before 0.2.8.15, 0.2.9.x before 0.2.9.12, 0.3.0.x before 0.3.0.11, 0.3.1.x before 0.3.1.7, and 0.3.2.x before 0.3.2.1-alpha, when SafeLogging is disabled, allows attackers to obtain sensitive information by leveraging access to the log files of a hidden service, because uninitialized stack data is included in an error message about construction of an introduction point circuit. |
| An issue was discovered in General Electric (GE) Proficy HMI/SCADA iFIX Version 5.8 SIM 13 and prior versions, Proficy HMI/SCADA CIMPLICITY Version 9.0 and prior versions, and Proficy Historian Version 6.0 and prior versions. An attacker may be able to retrieve user passwords if he or she has access to an authenticated session. |
| Akka versions <=2.4.16 and 2.5-M1 are vulnerable to a java deserialization attack in its Remoting component resulting in remote code execution in the context of the ActorSystem. |