| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability was found in SourceCodester Simple Company Website 1.0. It has been rated as critical. Affected by this issue is some unknown functionality of the file /classes/Content.php?f=service. The manipulation of the argument img leads to unrestricted upload. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. |
| D-Link DIR-823-Pro 1.02 has improper permission control, allowing unauthorized users to turn on and access Telnet services. |
| Insecure permissions in Silicon Labs (SiLabs) Z-Wave Series 700 and 800 v7.21.1 allow attackers to arbitrarily change the device type in the controller's memory, leading to a Denial of Service (DoS). |
| Insecure permissions in Silicon Labs (SiLabs) Z-Wave Series 700 and 800 v7.21.1 allow attackers to change the wakeup interval of end devices in controller memory, disrupting the device's communications with the controller. |
| Insecure permissions in Silicon Labs (SiLabs) Z-Wave Series 700 and 800 v7.21.1 allow attackers to cause disrupt communications between the controller and the device itself via repeatedly sending crafted packets to the controller. |
| Insecure permissions in Silicon Labs (SiLabs) Z-Wave Series 700 and 800 v7.21.1 allow attackers to cause a Denial of Service (DoS) via repeatedly sending crafted packets to the controller. |
| Insecure permissions in Silicon Labs (SiLabs) Z-Wave Series 700 and 800 v7.21.1 allow attackers to create a fake node via supplying crafted packets. |
| This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the onboardee module. The issue results from improper access control. An attacker can leverage this vulnerability to execute code in the context of root. |
| Improper authentication vulnerability in Rakuten WiFi Pocket all versions allows a network-adjacent attacker to log in to the product's Management Screen. As a result, sensitive information may be obtained and/or the settings may be changed. |
| An issue in Silicon Labs Z-Wave Series 500 v6.84.0 allows attackers to execute arbitrary code. |
| Silicon Labs Z-Wave Series 500 v6.84.0 was discovered to contain insecure permissions. |
| When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP that instructs the product to reset, a DoS can occur. This situation could cause loss of availability and a disruption of communication with other connected devices.
Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 |
| The Web server password authentication mechanism used by the products is vulnerable to a MitM and Replay attack. Successful exploitation of this vulnerability will allow unauthorized access of the product’s Web server to view and alter product configuration and diagnostics information.
Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 |
| When an affected
product receives a valid CIP message from an unauthorized or unintended
source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port
44818/UDP that changes the product’s configuration and network
parameters, a DoS condition can occur. This situation could cause loss
of availability and a disruption of communication with other connected
devices.
Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 |
| The device does not properly authenticate users and the potential exists for a remote user to upload a new firmware image to the Ethernet card, whether it is a corrupt or legitimate firmware image. Successful exploitation of this vulnerability could cause loss of availability, integrity, and confidentiality and a disruption in communications with other connected devices.
Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 |
| When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP that instructs the CPU to stop logic execution and enter a fault state, a DoS can occur. This situation could cause loss of availability and a disruption of communication with other connected devices.
Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 |
| IBM Performance Tools for i 7.2, 7.3, 7.4, and 7.5 could allow a local user to gain elevated privileges due to an unqualified library call. A malicious actor could cause user-controlled code to run with administrator privilege. IBM X-Force ID: 284563. |
| An issue was discovered in Veritas Backup Exec before 22.2 HotFix 917391. Improper access controls allow for DLL Hijacking in the Windows DLL Search path. |
| Insecure permissions in cert-manager v1.14.4 allows attackers to access sensitive data and escalate privileges by obtaining the service account's token. |
| A vulnerability, which was classified as critical, was found in zzskzy Warehouse Refinement Management System 3.1. Affected is the function ProcessRequest of the file /AcceptZip.ashx. The manipulation of the argument file leads to unrestricted upload. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |