| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| register.ghp in EFS Software Easy Chat Server versions 2.0 to 3.1 allows remote attackers to reset arbitrary passwords via a crafted POST request to registresult.htm. |
| In Wireshark 2.2.7, overly deep mp4 chunks may cause stack exhaustion (uncontrolled recursion) in the dissect_mp4_box function in epan/dissectors/file-mp4.c. |
| In Wireshark 2.2.7, deeply nested DAAP data may cause stack exhaustion (uncontrolled recursion) in the dissect_daap_one_tag function in epan/dissectors/packet-daap.c in the DAAP dissector. |
| Cacti 1.1.27 allows remote authenticated administrators to conduct Remote Code Execution attacks by placing the Log Path under the web root, and then making a remote_agent.php request containing PHP code in a Client-ip header. |
| The ReadDCMImage function in coders\dcm.c in ImageMagick 7.0.6-1 has an integer signedness error leading to excessive memory consumption via a crafted DCM file. |
| The aspath_put function in bgpd/bgp_aspath.c in Quagga before 1.2.2 allows remote attackers to cause a denial of service (session drop) via BGP UPDATE messages, because AS_PATH size calculation for long paths counts certain bytes twice and consequently constructs an invalid message. |
| The XML parsers in iText before 5.5.12 and 7.x before 7.0.3 do not disable external entities, which might allow remote attackers to conduct XML external entity (XXE) attacks via a crafted PDF. |
| 389-ds-base version before 1.3.5.19 and 1.3.6.7 are vulnerable to password brute-force attacks during account lockout due to different return codes returned on password attempts. |
| An issue in ZKTeko BioTime v.8.5.4 and before allows a remote attacker to obtain sensitive information via the Authentication & Authorization component |
| A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations. |
| A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations. |
| An “uninitialized variable” code execution vulnerability exists in the
Rockwell Automation Arena®
that could allow a threat actor to craft a DOE file and force the software to access a variable before it being initialized. If exploited, a threat actor could leverage this vulnerability to execute arbitrary code. To exploit this vulnerability, a legitimate user must execute the malicious code crafted by the threat actor. |
| In HCL Digital Experience, URLs can be constructed to redirect users to untrusted sites.
|
| In Multiple Locations, there is a possibility to launch arbitrary protected activities due to a confused deputy. This could lead to local escalation of privilege with User execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-13Android ID: A-242845514 |
| In onPreferenceClick of AccountTypePreferenceLoader.java, there is a possible way to retrieve protected files from the Settings app due to a confused deputy. This could lead to local information disclosure with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-13Android ID: A-220733496 |
| In SAP Solution Manager (Enterprise Search) - versions 740, and 750, an unauthenticated attacker can generate a link that, if clicked by a logged-in user, can be redirected to a malicious page that could read or modify sensitive information, or expose the user to a phishing attack, with little impact on confidentiality and integrity.
|
| HDF5 Library through 1.14.3 allows stack consumption in the function H5E_printf_stack in H5Eint.c. |
| mod_auth_openidc is an OpenID Certified™ authentication and authorization module for the Apache 2.x HTTP server. Versions prior to 2.4.12.2 are vulnerable to Open Redirect. When providing a logout parameter to the redirect URI, the existing code in oidc_validate_redirect_url() does not properly check for URLs that start with /\t, leading to an open redirect. This issue has been patched in version 2.4.12.2. Users unable to upgrade can mitigate the issue by configuring mod_auth_openidc to only allow redirection when the destination matches a given regular expression with OIDCRedirectURLsAllowed. |
| An authenticated user can perform XML eXternal Entity injection in Management Console in Symantec Identity Manager 14.4 |
| Improper initialization of x87 and SSE floating-point configuration registers in the __scone_entry component of SCONE before 5.8.0 for Intel SGX allows a local attacker to compromise the execution integrity of floating-point operations in an enclave or access sensitive information via side-channel analysis. |