| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Texas Instruments TI-RTOS, when configured to use HeapMem heap(default),
malloc returns a valid pointer to a small buffer on extremely large
values, which can trigger an integer overflow vulnerability in
'HeapMem_allocUnprotected' and result in code execution. |
| Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior lack proper validation of user-supplied data when parsing PRT files. This could lead to pointer dereferences of a value obtained from an untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. |
| Ypsomed mylife Cloud, mylife Mobile Application:Ypsomed mylife Cloud,All versions prior to 1.7.2,Ypsomed mylife App,All versions prior to 1.7.5,he Ypsomed mylife Cloud reflects the user password during the login process after redirecting the user from a HTTPS endpoint to a HTTP endpoint. |
| Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior lack proper validation of user-supplied data when parsing STP files. This could result in a stack-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. |
| Ypsomed mylife Cloud, mylife Mobile Application:Ypsomed mylife Cloud,All versions prior to 1.7.2,Ypsomed mylife App,All versions prior to 1.7.5,The Ypsomed mylife Cloud discloses password hashes during the registration process. |
| Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code. |
| ZOLL Defibrillator Dashboard, v prior to 2.2, The web application allows a non-administrative user to upload a malicious file. This file could allow an attacker to remotely execute arbitrary commands. |
| Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior lack proper validation of user-supplied data when parsing CATPart files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. |
| FATEK Automation WinProladder Versions 3.30 and prior is vulnerable to an integer underflow, which may cause an out-of-bounds write and allow an attacker to execute arbitrary code. |
| ZOLL Defibrillator Dashboard, v prior to 2.2,The application allows users to store their passwords in a recoverable format, which could allow an attacker to retrieve the credentials from the web browser. |
| ZOLL Defibrillator Dashboard, v prior to 2.2,The affected products contain insecure filesystem permissions that could allow a lower privilege user to escalate privileges to an administrative level user. |
| When JTEKT Corporation TOYOPUC PLC versions PC10G-CPU, 2PORT-EFR, Plus CPU, Plus EX, Plus EX2, Plus EFR, Plus EFR2, Plus 2P-EFR, PC10P-DP, PC10P-DP-IO, Plus BUS-EX, Nano 10GX, Nano 2ET,PC10PE, PC10PE-16/16P, PC10E, FL/ET-T-V2H, PC10B,PC10B-P, Nano CPU, PC10P, and PC10GE receive an invalid frame, the outside area of a receive buffer for FL-net are overwritten. As a result, the PLC CPU detects a system error, and the affected products stop. |
| A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected webserver applications allow access to stored data that can be obtained by using specially crafted URLs. |
| If Ethernet communication of the JTEKT Corporation TOYOPUC product series’ (TOYOPUC-PC10 Series: PC10G-CPU TCC-6353: All versions, PC10GE TCC-6464: All versions, PC10P TCC-6372: All versions, PC10P-DP TCC-6726: All versions, PC10P-DP-IO TCC-6752: All versions, PC10B-P TCC-6373: All versions, PC10B TCC-1021: All versions, PC10B-E/C TCU-6521: All versions, PC10E TCC-4737: All versions; TOYOPUC-Plus Series: Plus CPU TCC-6740: All versions, Plus EX TCU-6741: All versions, Plus EX2 TCU-6858: All versions, Plus EFR TCU-6743: All versions, Plus EFR2 TCU-6859: All versions, Plus 2P-EFR TCU-6929: All versions, Plus BUS-EX TCU-6900: All versions; TOYOPUC-PC3J/PC2J Series: FL/ET-T-V2H THU-6289: All versions, 2PORT-EFR THU-6404: All versions) are left in an open state by an attacker, Ethernet communications cannot be established with other devices, depending on the settings of the link parameters. |
| A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected products utilize a weak encryption algorithm for storage of sensitive data, which may allow an attacker to more easily obtain credentials used for access. |
| The software performs an operation at a privilege level higher than the minimum level required, which creates new weaknesses or amplifies the consequences of other weaknesses on the Reason DR60 (all firmware versions prior to 02A04.1). |
| Mesa Labs AmegaView Versions 3.0 uses default cookies that could be set to bypass authentication to the web application, which may allow an attacker to gain access. |
| The software contains a hard-coded password that could allow an attacker to take control of the merging unit using these hard-coded credentials on the MU320E (all firmware versions prior to v04A00.1). |
| Mesa Labs AmegaView Versions 3.0 and prior’s passcode is generated by an easily reversible algorithm, which may allow an attacker to gain access to the device. |
| SSH server configuration file does not implement some best practices. This could lead to a weakening of the SSH protocol strength, which could lead to additional misconfiguration or be leveraged as part of a larger attack on the MU320E (all firmware versions prior to v04A00.1). |