Export limit exceeded: 350801 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (80669 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2021-27432 | 1 Opcfoundation | 2 Ua-.net-legacy, Ua .net Standard Stack | 2024-11-21 | 7.5 High |
| OPC Foundation UA .NET Standard versions prior to 1.4.365.48 and OPC UA .NET Legacy are vulnerable to an uncontrolled recursion, which may allow an attacker to trigger a stack overflow. | ||||
| CVE-2021-27429 | 1 Ti | 14 Cc3200, Cc3220r, Cc3220s and 11 more | 2024-11-21 | 7.4 High |
| Texas Instruments TI-RTOS returns a valid pointer to a small buffer on extremely large values. This can trigger an integer overflow vulnerability in 'HeapTrack_alloc' and result in code execution. | ||||
| CVE-2021-27413 | 1 Omron | 2 Cx-one, Cx-server | 2024-11-21 | 7.8 High |
| Omron CX-One Versions 4.60 and prior, including CX-Server Versions 5.0.29.0 and prior, are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code. | ||||
| CVE-2021-27412 | 1 Deltaww | 1 Dopsoft | 2024-11-21 | 7.8 High |
| Delta Electronics DOPSoft Versions 4.0.10.17 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code. | ||||
| CVE-2021-27408 | 1 Hillrom | 9 Connex Central Station, Connex Device Integration Suite Network Connectivity Engine, Connex Integrated Wall System and 6 more | 2024-11-21 | 7.5 High |
| The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00). | ||||
| CVE-2021-27405 | 1 Scrapbox-parser Project | 1 Scrapbox-parser | 2024-11-21 | 7.5 High |
| A ReDoS (regular expression denial of service) flaw was found in the @progfay/scrapbox-parser package before 6.0.3 for Node.js. | ||||
| CVE-2021-27400 | 1 Hashicorp | 1 Vault | 2024-11-21 | 7.5 High |
| HashiCorp Vault and Vault Enterprise Cassandra integrations (storage backend and database secrets engine plugin) did not validate TLS certificates when connecting to Cassandra clusters. Fixed in 1.6.4 and 1.7.1 | ||||
| CVE-2021-27399 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 7.8 High |
| A vulnerability has been identified in Simcenter Femap 2020.2 (All versions < V2020.2.MP3), Simcenter Femap 2021.1 (All versions < V2021.1.MP3). The femap.exe application lacks proper validation of user-supplied data when parsing FEMAP files. This could result in an out of bounds write past the end of an allocated structure, a different vulnerability than CVE-2021-27387. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12820) | ||||
| CVE-2021-27398 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-11-21 | 7.8 High |
| A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27396. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13290) | ||||
| CVE-2021-27397 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-11-21 | 7.8 High |
| A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13287) | ||||
| CVE-2021-27396 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-11-21 | 7.8 High |
| A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27398. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13279) | ||||
| CVE-2021-27395 | 1 Siemens | 4 Simatic Process Historian 2013, Simatic Process Historian 2014, Simatic Process Historian 2019 and 1 more | 2024-11-21 | 8.1 High |
| A vulnerability has been identified in SIMATIC Process Historian 2013 and earlier (All versions), SIMATIC Process Historian 2014 (All versions < SP3 Update 6), SIMATIC Process Historian 2019 (All versions), SIMATIC Process Historian 2020 (All versions). An interface in the software that is used for critical functionalities lacks authentication, which could allow a malicious user to maliciously insert, modify or delete data. | ||||
| CVE-2021-27394 | 1 Mendix | 1 Mendix | 2024-11-21 | 8.8 High |
| A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.19), Mendix Applications using Mendix 8 (All versions < V8.17.0), Mendix Applications using Mendix 8 (V8.12) (All versions < V8.12.5), Mendix Applications using Mendix 8 (V8.6) (All versions < V8.6.9), Mendix Applications using Mendix 9 (All versions < V9.0.5). Authenticated, non-administrative users could modify their privileges by manipulating the user role under certain circumstances, allowing them to gain administrative privileges. | ||||
| CVE-2021-27392 | 1 Siemens | 1 Siveillance Video Open Network Bridge | 2024-11-21 | 8.8 High |
| A vulnerability has been identified in Siveillance Video Open Network Bridge (2020 R3), Siveillance Video Open Network Bridge (2020 R2), Siveillance Video Open Network Bridge (2020 R1), Siveillance Video Open Network Bridge (2019 R3), Siveillance Video Open Network Bridge (2019 R2), Siveillance Video Open Network Bridge (2019 R1), Siveillance Video Open Network Bridge (2018 R3), Siveillance Video Open Network Bridge (2018 R2). Affected Open Network Bridges store user credentials for the authentication between ONVIF clients and ONVIF server using a hard-coded key. The encrypted credentials can be retrieved via the MIP SDK. This could allow an authenticated remote attacker to retrieve and decrypt all credentials stored on the ONVIF server. | ||||
| CVE-2021-27390 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2024-11-21 | 7.8 High |
| A vulnerability has been identified in JT2Go (All versions < V13.1.0.3), Teamcenter Visualization (All versions < V13.1.0.3). The TIFF_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13131) | ||||
| CVE-2021-27387 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 7.8 High |
| A vulnerability has been identified in Simcenter Femap 2020.2 (All versions < V2020.2.MP3), Simcenter Femap 2021.1 (All versions < V2021.1.MP3). The femap.exe application lacks proper validation of user-supplied data when parsing FEMAP files. This could result in an out of bounds write past the end of an allocated structure, a different vulnerability than CVE-2021-27399. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12819) | ||||
| CVE-2021-27386 | 1 Siemens | 35 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 32 more | 2024-11-21 | 7.5 High |
| A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition. | ||||
| CVE-2021-27385 | 1 Siemens | 35 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 32 more | 2024-11-21 | 7.5 High |
| A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition. | ||||
| CVE-2021-27383 | 1 Siemens | 35 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 32 more | 2024-11-21 | 7.5 High |
| A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition. | ||||
| CVE-2021-27382 | 1 Siemens | 2 Solid Edge Se2020, Solid Edge Se2021 | 2024-11-21 | 7.8 High |
| A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13040) | ||||