Search Results (2301 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2016-15044 2026-04-15 N/A
A remote code execution vulnerability exists in Kaltura versions prior to 11.1.0-2 due to unsafe deserialization of user-controlled data within the keditorservices module. An unauthenticated remote attacker can exploit this issue by sending a specially crafted serialized PHP object in the kdata GET parameter to the redirectWidgetCmd endpoint. Successful exploitation leads to execution of arbitrary PHP code in the context of the web server process.
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-34037 1 Linksys 6 E1000, E1200, E1500 and 3 more 2026-04-15 N/A
An OS command injection vulnerability exists in various models of E-Series Linksys routers via the /tmUnblock.cgi and /hndUnblock.cgi endpoints over HTTP on port 8080. The CGI scripts improperly process user-supplied input passed to the ttcp_ip parameter without sanitization, allowing unauthenticated attackers to inject shell commands. This vulnerability was reported to be exploited in the wild by the "TheMoon" worm  in 2014 to deploy a MIPS ELF payload, enabling arbitrary code execution on the router. Additionally, this vulnerability may affect other Linksys products to include, but not limited to, WAG/WAP/WES/WET/WRT-series router models and Wireless-N access points and routers. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-06 UTC.
CVE-2021-47744 2 Cypress, Linux 3 Ctm-200, Ctm-one, Linux 2026-04-15 7.5 High
Cypress Solutions CTM-200/CTM-ONE 1.3.6 contains hard-coded credentials vulnerability in Linux distribution that exposes root access. Attackers can exploit the static 'Chameleon' password to gain remote root access via Telnet or SSH on affected devices.
CVE-2024-11737 2026-04-15 9.8 Critical
CWE-20: Improper Input Validation vulnerability exists that could lead to a denial of service and a loss of confidentiality, integrity of the controller when an unauthenticated crafted Modbus packet is sent to the device.
CVE-2024-13984 2026-04-15 N/A
QiAnXin TianQing Management Center versions up to and including 6.7.0.4130 contain a path traversal vulnerability in the rptsvr component that allows unauthenticated attackers to upload files to arbitrary locations on the server. The /rptsvr/upload endpoint fails to sanitize the filename parameter in multipart form-data requests, enabling path traversal. This allows attackers to place executable files in web-accessible directories, potentially leading to remote code execution. Exploitation evidence was first observed by the Shadowserver Foundation on 2024-08-23 UTC.
CVE-2024-43648 2026-04-15 8.8 High
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).  A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2025-34319 1 Totolink 2 N300rt, N300rt Firmware 2026-04-15 N/A
TOTOLINK N300RT wireless router firmware versions prior to V3.4.0-B20250430 (discovered in V2.1.8-B20201030.1539) contain an OS command injection vulnerability in the Boa formWsc handling functionality. An unauthenticated attacker can send specially crafted requests to trigger command execution via the targetAPSsid request parameter.
CVE-2024-21576 2026-04-15 10 Critical
ComfyUI-Bmad-Nodes is vulnerable to Code Injection. The issue stems from a validation bypass in the BuildColorRangeHSVAdvanced, FilterContour and FindContour custom nodes. In the entrypoint function to each node, there’s a call to eval which can be triggered by generating a workflow that injects a crafted string into the node. This can result in executing arbitrary code on the server.
CVE-2015-10141 2026-04-15 5.6 Medium
An unauthenticated OS command injection vulnerability exists within Xdebug versions 2.5.5 and earlier, a PHP debugging extension developed by Derick Rethans. When remote debugging is enabled, Xdebug listens on port 9000 and accepts debugger protocol commands without authentication. An attacker can send a crafted eval command over this interface to execute arbitrary PHP code, which may invoke system-level functions such as system() or passthru(). This results in full compromise of the host under the privileges of the web server user.
CVE-2023-7311 1 Bytevalue 1 Flow Control Router 2026-04-15 N/A
BYTEVALUE Intelligent Flow Control Router contains a command injection vulnerability via the /goform/webRead/open endpoint. The `path` parameter is not properly validated and is echoed into a shell context, allowing an attacker to inject and execute arbitrary shell commands on the device. Successful exploitation can lead to writing backdoors, privilege escalation on the host, and full compromise of the router and its management functions. VulnCheck has observed this vulnerability being targeted by the RondoDox botnet campaign.
CVE-2025-61934 1 Automationdirect 8 P1-540, P1-550, P2-550 and 5 more 2026-04-15 10 Critical
A binding to an unrestricted IP address vulnerability was discovered in Productivity Suite software version v4.4.1.19. The vulnerability allows an unauthenticated remote attacker to interact with the ProductivityService PLC simulator and read, write, or delete arbitrary files and folders on the target machine
CVE-2025-54473 1 Joomla 2 Joomla, Joomla! 2026-04-15 N/A
An authenticated RCE vulnerability in Phoca Commander component 1.0.0-4.0.0 and 5.0.0-5.0.1 for Joomla was discovered. The issue allows code execution via the unzip feature.
CVE-2025-64310 2 Epson, Seiko Epson Corporation 2 Webconfig, Web Config 2026-04-15 9.8 Critical
EPSON WebConfig and Epson Web Control for SEIKO EPSON Projector Products do not restrict excessive authentication attempts. An administrative user's password may be identified through a brute force attack.
CVE-2025-52551 2026-04-15 N/A
E2 Facility Management Systems use a proprietary protocol that allows for unauthenticated file operations on any file in the file system.
CVE-2025-54120 1 Pcl 1 Pcl2-ce 2026-04-15 N/A
PCL (Plain Craft Launcher) Community Edition is a Minecraft launcher. In PCL CE versions 2.12.0-beta.5 to 2.12.0-beta.9, the login credentials used during the third-party login process are accidentally recorded in the local log file. Although the log file is not automatically uploaded or shared, if the user manually sends the log file, there is a risk of leakage. This is fixed in version 2.12.0-beta.10.
CVE-2025-12108 1 Survision 1 License Plate Recognition Camera 2026-04-15 N/A
The Survision LPR Camera system does not enforce password protection by default. This allows access to the configuration wizard immediately without a login prompt or credentials check.
CVE-2021-4464 1 Fiberhome 4 An5506-04-fa, An5506-04-fa Firmware, Hg6245d and 1 more 2026-04-15 N/A
FiberHome AN5506-04-FA firmware versions up to and including RP2631 and HG6245D prior to RP2602 contain a stack-based buffer overflow, as the HTTP service ('webs') fails to enforce maximum lengths for Cookie header values. When a cookie longer than 511 bytes is processed, a stack buffer is overrun, leading to a crash or potential control of execution flow.
CVE-2023-4976 1 Purestorage 1 Flashblade 2026-04-15 N/A
A flaw exists in FlashBlade whereby a local account is permitted to authenticate to the management interface using an unintended method that allows an attacker to gain privileged access to the array.