| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue was discovered on LG mobile devices with Android OS 8.0, 8.1, 9.0, and 10 software. System services may crash because of the lack of a NULL parameter check. The LG ID is LVE-SMP-200024 (November 2020). |
| An issue was discovered on Samsung mobile devices with P(9.0) and Q(10.0) (Exynos 980, 9820, and 9830 chipsets) software. The NPU driver allows attackers to execute arbitrary code because of unintended write and read operations on memory. The Samsung ID is SVE-2020-18610 (November 2020). |
| An issue was discovered on Samsung mobile devices with P(9.0) and Q(10.0) (China / India) software. The S Secure application allows attackers to bypass authentication for a locked Gallery application via the Reminder application. The Samsung ID is SVE-2020-18689 (November 2020). |
| An issue was discovered on Samsung mobile devices with Q(10.0) (Exynos990 chipsets) software. The S3K250AF Secure Element CC EAL 5+ chip allows attackers to execute arbitrary code and obtain sensitive information via a buffer overflow. The Samsung ID is SVE-2020-18632 (November 2020). |
| A directory traversal issue in the Utils/Unzip module in Microweber through 1.1.20 allows an authenticated attacker to gain remote code execution via the backup restore feature. To exploit the vulnerability, an attacker must have the credentials of an administrative user, upload a maliciously constructed ZIP file with file paths including relative paths (i.e., ../../), move this file into the backup directory, and execute a restore on this file. |
| Barco wePresent WiPG-1600W devices have Improper Access Control. Affected Version(s): 2.5.1.8. The Barco wePresent WiPG-1600W device has an SSH daemon included in the firmware image. By default, the SSH daemon is disabled and does not start at system boot. The system initialization scripts read a device configuration file variable to see if the SSH daemon should be started. The web interface does not provide a visible capability to alter this configuration file variable. However, a malicious actor can include this variable in a POST such that the SSH daemon will be started when the device boots. |
| SuiteCRM before 7.11.17 is vulnerable to remote code execution via the system settings Log File Name setting. In certain circumstances involving admin account takeover, logger_file_name can refer to an attacker-controlled .php file under the web root. |
| Prototype pollution vulnerability in 'controlled-merge' versions 1.0.0 through 1.2.0 allows attacker to cause a denial of service and may lead to remote code execution. |
| Prototype pollution vulnerability in '@strikeentco/set' version 1.0.0 allows attacker to cause a denial of service and may lead to remote code execution. |
| NETSCOUT AirMagnet Enterprise 11.1.4 build 37257 and earlier has a sensor escalated privileges vulnerability that can be exploited to provide someone with administrative access to a sensor, with credentials to invoke a command to provide root access to the operating system. The attacker must complete a straightforward password-cracking exercise. |
| An integer overflow in the PngImg::InitStorage_() function of png-img before 3.1.0 leads to an under-allocation of heap memory and subsequently an exploitable heap-based buffer overflow when loading a crafted PNG file. |
| An issue was discovered in SaltStack Salt before 3002.5. The minion's restartcheck is vulnerable to command injection via a crafted process name. This allows for a local privilege escalation by any user able to create a files on the minion in a non-blacklisted directory. |
| A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 (Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1) and EcoStruxure Geo SCADA Expert 2020 (Original release and Monthly Updates to September 2020, from 83.7551.1 to 83.7578.1), that could cause exposure of credentials to server-side users when web users are logged in to Virtual ViewX. |
| A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to read network traffic over HTTP protocol. |
| A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to read network traffic over HTTP protocol. |
| A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending specially crafted requests over Modbus. |
| A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger. |
| The 'id' parameter of IBM Tivoli Storage Manager Version 5 Release 2 (Command Line Administrative Interface, dsmadmc.exe) is vulnerable to an exploitable stack buffer overflow. Note: the vulnerability can be exploited when it is used in "interactive" mode while, cause of a max number characters limitation, it cannot be exploited in batch or command line usage (e.g. dsmadmc.exe -id=username -password=pwd). NOTE: This vulnerability only affects products that are no longer supported by the maintainer |
| Email Injection in TerraMaster TOS <= 4.2.06 allows remote unauthenticated attackers to abuse the forget password functionality and achieve account takeover. |
| There is a local privilege escalation vulnerability in Alfredo Milani Comparetti SpeedFan 4.52. Attackers can use constructed programs to increase user privileges |