| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Selea CarPlateServer 4.0.1.6 contains a remote program execution vulnerability that allows attackers to execute arbitrary Windows binaries by manipulating the NO_LIST_EXE_PATH configuration parameter. Attackers can bypass authentication through the /cps/ endpoint and modify server configuration, including changing admin passwords and executing system commands. |
| Amazon EMR Secret Agent creates a keytab file containing Kerberos credentials. This file is stored in the /tmp/ directory. A user with access to this directory and another account can potentially decrypt the keys and escalate to higher privileges.
Users are advised to upgrade to Amazon EMR version 7.5 or higher. For Amazon EMR releases between 6.10 and 7.4, we strongly recommend that you run the bootstrap script and RPM files with the fix provided in the location below. |
| A remote, unauthenticated privilege escalation in ibi WebFOCUS allows an attacker to gain administrative access to the application which may lead to unauthenticated Remote Code Execution |
| Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in Newtec NTC2218, NTC2250, NTC2299 on Linux, PowerPC, ARM (Updating signaling process in the swdownload binary modules) allows Local Execution of Code, Remote Code Inclusion.
This issue affects NTC2218, NTC2250, NTC2299: from 1.0.1.1 through 2.2.6.19. The issue is both present on the PowerPC versions of the modem and the ARM versions.
A stack buffer buffer overflow in the swdownload binary allows attackers to execute arbitrary code. The parse_INFO function uses an unrestricted `sscanf` to read a string of an incoming network packet into a statically sized buffer. |
| The web application uses a weak authentication mechanism to verify that a request is coming from an authenticated and authorized resource. |
| Atheos is a self-hosted browser-based cloud integrated development environment. Prior to version 6.0.4, improper use of `escapeshellcmd()` in `/components/codegit/traits/execute.php` allows argument injection, leading to arbitrary command execution. Atheos administrators and users of vulnerable versions are at risk of data breaches or server compromise. Version 6.0.4 introduces a `Common::safe_execute` function that sanitizes all arguments using `escapeshellarg()` prior to execution and migrated all components potentially vulnerable to similar exploits to use this new templated execution system. |
| A Missing Authorization vulnerability in SUSE Linux Manager allows anyone with the ability to connect to port 443 of SUSE Manager is able to run any command as root on any client. This issue affects Container suse/manager/5.0/x86_64/server:5.0.5.7.30.1: from ? before 5.0.27-150600.3.33.1; Image SLES15-SP4-Manager-Server-4-3-BYOS: from ? before 4.3.87-150400.3.110.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-Azure: from ? before 4.3.87-150400.3.110.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-EC2: from ? before 4.3.87-150400.3.110.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-GCE: from ? before 4.3.87-150400.3.110.2; SUSE Manager Server Module 4.3: from ? before 4.3.87-150400.3.110.2. |
| Missing Authentication for Critical Function, Missing Authorization vulnerability in Nomysoft Informatics Nomysem allows Collect Data as Provided by Users.This issue affects Nomysem: before 13.10.2024. |
| Improper neutralization of input provided by an unauthorized user into changes__reference_id parameter in URL allows for boolean-based Blind SQL Injection attacks. |
| A vulnerability has been identified in Industrial Edge Management Pro (All versions < V1.9.5), Industrial Edge Management Virtual (All versions < V2.3.1-1). Affected components do not properly validate the device tokens. This could allow an unauthenticated remote attacker to impersonate other devices onboarded to the system. |
| A denial-of-service vulnerability exists in the Rockwell Automation Power Monitor 1000. The vulnerability results in a buffer-overflow, potentially causing denial-of-service. |
| A denial-of-service and possible remote code execution vulnerability exists in the Rockwell Automation Power Monitor 1000. The vulnerability results in corruption of the heap memory which may compromise the integrity of the system, potentially allowing for remote code execution or a denial-of-service attack. |
| A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6.0 (All versions < V6.0 SP12 Upd3), Automation License Manager V6.2 (All versions < V6.2 Upd3). Affected applications do not properly validate certain fields in incoming network packets on port 4410/tcp. This could allow an unauthenticated remote attacker to cause an integer overflow and crash of the application. This denial of service condition could prevent legitimate users from using subsequent products that rely on the affected application for license verification. |
| Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in Exnet Informatics Software Ferry Reservation System allows SQL Injection.This issue affects Ferry Reservation System: before 240805-002. |
| Kieback & Peter's DDC4000 series uses weak credentials, which may allow an unauthenticated attacker to get full admin rights on the system. |
| An authentication bypass vulnerability in Korenix JetPort 5601v3 allows an attacker to access functionality on the device without specifying a password.This issue affects JetPort 5601v3: through 1.2. |
| When the device is shared, the homepage module are before 2.19.0 in eWeLink Cloud Service allows Secondary user to take over devices as primary user via sharing unnecessary device-sensitive information. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| OMNTEC Proteus Tank Monitoring OEL8000III Series
could allow an attacker to perform administrative actions without proper authentication. |
| An authentication bypass vulnerability has been identified in the REST and SOAP API components of Tripwire Enterprise (TE) 9.1.0 when TE is configured to use LDAP/Active Directory SAML authentication and its optional "Auto-synchronize LDAP Users, Roles, and Groups" feature is enabled. This vulnerability allows unauthenticated attackers to bypass authentication if a valid username is known. Exploitation of this vulnerability could allow remote attackers to gain privileged access to the APIs and lead to unauthorized information disclosure or modification. |