Export limit exceeded: 348228 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (18906 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2021-27472 | 1 Rockwellautomation | 1 Factorytalk Assetcentre | 2025-04-16 | 10 Critical |
| A vulnerability exists in the RunSearch function of SearchService service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier, which may allow for the execution of remote unauthenticated arbitrary SQL statements. | ||||
| CVE-2021-27468 | 1 Rockwellautomation | 1 Factorytalk Assetcentre | 2025-04-16 | 10 Critical |
| The AosService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier exposes functions lacking proper authentication. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary SQL statements. | ||||
| CVE-2022-26059 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 9.8 Critical |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability that exists in GetQueryData. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||||
| CVE-2022-25980 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 9.8 Critical |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability that exists in HandlerCommon.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||||
| CVE-2022-26069 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 9.8 Critical |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability that exists in HandlerPage_KID.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||||
| CVE-2022-0923 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 9.8 Critical |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability that exists in HandlerDialog_KID.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||||
| CVE-2022-25880 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 9.8 Critical |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in HandlerTag_KID.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||||
| CVE-2022-26013 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 9.8 Critical |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability that exists in DIAE_dmdsetHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||||
| CVE-2022-26065 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 9.8 Critical |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in GetLatestDemandNode. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||||
| CVE-2022-26349 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 9.8 Critical |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability that exists in DIAE_eccoefficientHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||||
| CVE-2022-26836 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 9.8 Critical |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability that exists in HandlerExport.ashx/Calendar. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||||
| CVE-2022-26887 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 9.8 Critical |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_loopmapHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||||
| CVE-2022-26666 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 9.8 Critical |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in HandlerECC.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||||
| CVE-2022-26514 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 9.8 Critical |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability that exists in DIAE_tagHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||||
| CVE-2022-26338 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 9.8 Critical |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in HandlerPageP_KID.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||||
| CVE-2022-26667 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 9.8 Critical |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability that exists in GetDemandAnalysisData. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||||
| CVE-2022-27175 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 9.8 Critical |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability that exists in GetCalcTagList. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||||
| CVE-2021-32953 | 1 Auvesy-mdt | 2 Autosave, Autosave For System Platform | 2025-04-16 | 9.8 Critical |
| An attacker could utilize SQL commands to create a new user MDT AutoSave versions prior to v6.02.06 and update the user’s permissions, granting the attacker the ability to login. | ||||
| CVE-2021-32957 | 1 Auvesy-mdt | 2 Autosave, Autosave For System Platform | 2025-04-16 | 7.5 High |
| A function in MDT AutoSave versions prior to v6.02.06 is used to retrieve system information for a specific process, and this information collection executes multiple commands and summarizes the information into an XML. This function and subsequent process gives full path to the executable and is therefore vulnerable to binary hijacking. | ||||
| CVE-2022-1366 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 9.8 Critical |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in HandlerChart.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||||