| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| PLANEX CS-QP50F-ING2 smart cameras expose a configuration backup interface over HTTP that does not require authentication. A remote, unauthenticated attacker can directly retrieve a compressed configuration backup file from the device. The backup contains sensitive configuration information, including credentials, allowing an attacker to obtain administrative access to the camera and compromise the confidentiality of the monitored environment. |
| Peppermint Ticket Management 0.4.6 is vulnerable to Incorrect Access Control. A regular registered user is able to elevate his privileges to admin and gain complete access to the system as the authorization mechanism is not validated on the server side and only on the client side. This can result, for example, in creating a new admin user in the system which enables persistent access for the attacker as an administrator. |
| Pix-Link LV-WR21Q does not enforce any form of authentication for endpoint /goform/getHomePageInfo. Remote unauthenticated attacker is able to use this endpoint to e.g: retrieve cleartext password to the access point.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version V108_108 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| Denver SHO-110 IP cameras expose a secondary HTTP service on TCP port 8001 that provides access to a '/snapshot' endpoint without authentication. While the primary web interface on port 80 enforces authentication, the backdoor service allows any remote attacker to retrieve image snapshots by directly requesting the 'snapshot' endpoint. An attacker can repeatedly collect snapshots and reconstruct the camera stream, compromising the confidentiality of the monitored environment. |
| TEM Opera Plus FM Family Transmitter allows access to an unprotected endpoint that allows MPFS File System binary image upload without authentication. This file system serves as the basis for the HTTP2 web server module but is also used by the SNMP module and is available to other applications that require basic read-only storage capabilities. This can be exploited to overwrite the flash program memory that holds the web server's main interfaces and execute arbitrary code. |
| An Incorrect Implementation of Authentication Algorithm and Exposure of Data Element to Wrong Ses-sion vulnerability in the session handling used in B&R APROL <4.4-00P5 may allow an authenticated network attacker to take over a currently active user session without login credentials. |
| Burk Technology ARC Solo's password change mechanism can be utilized without proper
authentication procedures, allowing an attacker to take over the device.
A password change request can be sent directly to the device's HTTP
endpoint without providing valid credentials. The system does not
enforce proper authentication or session validation, allowing the
password change to proceed without verifying the request's legitimacy. |
| The ASPECT system allows users to bypass authentication.
This issue affects all versions of ASPECT |
| An insufficient entropy vulnerability in the SecuSUITE Secure Client Authentication (SCA) Server of SecuSUITE versions 5.0.420 and earlier could allow an attacker to potentially enroll an attacker-controlled device to the victim’s account and telephone number. |
| The wifi module exposes the interface and has improper permission control, leaking sensitive information about the device. |
| General Industrial Controls Lynx+ Gateway is missing critical authentication in the embedded web server which
could allow an attacker to send GET requests to obtain sensitive device
information. |
| Siklu MultiHaul TG series devices before version 2.0.0 contain an unauthenticated vulnerability that allows remote attackers to retrieve randomly generated credentials via a network request. Attackers can send a specific hex-encoded command to port 12777 to obtain username and password, enabling direct SSH access to the device. |
| In WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) due to lack of authentication in the configuration change module in the adm.cgi endpoint, the unauthenticated attacker can execute commands including backup creation, device restart and resetting the device to factory settings.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| In One Identity Identity Manager 9.x before 9.3, an insecure direct object reference (IDOR) vulnerability allows privilege escalation. Only On-Premise installations are affected. |
| dectalk-tts is a Node package to interact with the aeiou Dectalk web API. In `dectalk-tts@1.0.0`, network requests to the third-party API are sent over HTTP, which is unencrypted. Unencrypted traffic can be easily intercepted and modified by attackers. Anyone who uses the package could be the victim of a man-in-the-middle (MITM) attack. The network request was upgraded to HTTPS in version `1.0.1`. There are no workarounds, but some precautions include not sending any sensitive information and carefully verifying the API response before saving it. |
| Webhood is a self-hosted URL scanner used analyzing phishing and malicious sites. Webhood's backend container images in versions 0.9.0 and earlier are subject to Missing Authentication for Critical Function vulnerability. This vulnerability allows an unauthenticated attacker to send a HTTP request to the database (Pocketbase) admin API to create an admin account. The Pocketbase admin API does not check for authentication/authorization when creating an admin account when no admin accounts have been added. In its default deployment, Webhood does not create a database admin account. Therefore, unless users have manually created an admin account in the database, an admin account will not exist in the deployment and the deployment is vulnerable. Versions starting from 0.9.1 are patched. The patch creates a randomly generated admin account if admin accounts have not already been created i.e. the vulnerability is exploitable in the deployment. As a workaround, users can disable access to URL path starting with `/api/admins` entirely. With this workaround, the vulnerability is not exploitable via network. |
| WGS-80HPT-V2 and WGS-4215-8T2S are missing authentication that could
allow an attacker to create an administrator account without knowing any
existing credentials. |
| An issue in the BYD Dilink Headunit System v3.0 to v4.0 allows attackers to bypass authentication via a bruteforce attack. |
| Instantel Micromate lacks authentication on a configuration port which could allow an attacker to execute commands if connected. |
| The CE21 Suite plugin for WordPress is vulnerable to unauthorized plugin settings update due to a missing capability check on the wp_ajax_nopriv_ce21_single_sign_on_save_api_settings AJAX action in versions 2.2.1 to 2.3.1. This makes it possible for unauthenticated attackers to update the plugin's API settings including a secret key used for authentication. This allows unauthenticated attackers to create new admin accounts on an affected site. |