Search Results (806 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2018-1124 6 Canonical, Debian, Opensuse and 3 more 13 Ubuntu Linux, Debian Linux, Leap and 10 more 2025-12-18 7.8 High
procps-ng before version 3.3.15 is vulnerable to multiple integer overflows leading to a heap corruption in file2strvec function. This allows a privilege escalation for a local attacker who can create entries in procfs by starting processes, which could result in crashes or arbitrary code execution in proc utilities run by other users.
CVE-2018-1126 5 Canonical, Debian, Procps-ng Project and 2 more 13 Ubuntu Linux, Debian Linux, Procps-ng and 10 more 2025-12-17 N/A
procps-ng before version 3.3.15 is vulnerable to an incorrect integer size in proc/alloc.* leading to truncation/integer overflow issues. This flaw is related to CVE-2018-1124.
CVE-2014-5413 2 Aveva, Schneider-electric 2 Clearscada, Scada Expert Clearscada 2025-11-04 N/A
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm.
CVE-2014-5412 2 Aveva, Schneider-electric 2 Clearscada, Scada Expert Clearscada 2025-11-04 N/A
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account.
CVE-2014-5411 2 Aveva, Schneider-electric 2 Clearscada, Scada Expert Clearscada 2025-11-04 N/A
Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors.
CVE-2014-5407 1 Schneider-electric 1 Vampset 2025-11-03 N/A
Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.
CVE-2018-7841 1 Schneider-electric 1 U.motion Builder 2025-11-03 9.8 Critical
A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an improper set of characters is entered.
CVE-2019-6833 1 Schneider-electric 49 Hmig2u, Hmig3u, Hmig3ufc and 46 more 2025-09-30 6.5 Medium
A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high rate of frames is received. When the attack stops, the buffered commands are processed by the HMI panel.
CVE-2023-5984 1 Schneider-electric 4 Ion8650, Ion8650 Firmware, Ion8800 and 1 more 2025-09-30 7.2 High
A CWE-494 Download of Code Without Integrity Check vulnerability exists that could allow modified firmware to be uploaded when an authorized admin user begins a firmware update procedure which could result in full control over the device.
CVE-2014-0789 1 Schneider-electric 5 Opc Factory Server Tlxcdlfofs, Opc Factory Server Tlxcdltofs, Opc Factory Server Tlxcdluofs and 2 more 2025-09-25 N/A
Multiple buffer overflows in the OPC Automation 2.0 Server Object ActiveX control in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 3.5 and earlier, TLXCDSTOFS33 3.5 and earlier, TLXCDLUOFS33 3.5 and earlier, TLXCDLTOFS33 3.5 and earlier, and TLXCDLFOFS33 3.5 and earlier allow remote attackers to cause a denial of service via long arguments to unspecified functions.
CVE-2014-0774 1 Schneider-electric 6 Ofs Test Client Tlxcdlfofs33, Ofs Test Client Tlxcdltofs33, Ofs Test Client Tlxcdluofs33 and 3 more 2025-09-24 N/A
Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.
CVE-2021-22825 1 Schneider-electric 4 Rack Power Distribution Unit With Network Management Card 2, Rack Power Distribution Unit With Network Management Card 2 Firmware, Rack Power Distribution Unit With Network Management Card 3 and 1 more 2025-09-08 8 High
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could allow an attacker to access the system with elevated privileges when a privileged account clicks on a malicious URL that compromises the security token. Affected Products: AP7xxxx and AP8xxx with NMC2 (V6.9.6 or earlier), AP7xxx and AP8xxx with NMC3 (V1.1.0.3 or earlier), and APDU9xxx with NMC3 (V1.0.0.28 or earlier)
CVE-2014-9200 1 Schneider-electric 4 Somachine, Somove, Somove Lite and 1 more 2025-09-05 N/A
Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors.
CVE-2014-9198 1 Schneider-electric 5 Etg3000 Factorycast Hmi Gateway Firmware, Tsxetg3000, Tsxetg3010 and 2 more 2025-09-05 N/A
The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session.
CVE-2014-9197 1 Schneider-electric 5 Etg3000 Factorycast Hmi Gateway Firmware, Tsxetg3000, Tsxetg3010 and 2 more 2025-09-05 N/A
The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request.
CVE-2024-5681 2 Schneider-electric, Schneider Electric 2 Ecostruxure Foxboro Dcs Control Core Services, Ecostruxure Foxboro Dcs Core Control Services 2025-08-27 7.8 High
CWE-20: Improper Input Validation vulnerability exists that could cause local denial-of-service, privilege escalation, and potentially kernel execution when a malicious actor with local user access crafts a script/program using an IOCTL call in the Foxboro.sys driver.
CVE-2014-0754 1 Schneider-electric 86 171ccc96020, 171ccc96020 Firmware, 171ccc96020c and 83 more 2025-08-26 N/A
Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, TSXETC101 Exec before 2.04, TSXETY4103x Exec before 5.7, TSXETY5103x Exec before 5.9, TSXP57x ETYPort Exec before 5.7, and TSXP57x Ethernet Copro Exec before 5.5 allows remote attackers to visit arbitrary resources via a crafted HTTP request.
CVE-2014-9190 1 Schneider-electric 1 Wonderware Intouch Access Anywhere Server 2025-07-24 N/A
Stack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrary code via a request for a filename that does not exist.
CVE-2020-7533 1 Schneider-electric 32 140cpu65260, 140cpu65260 Firmware, 140noc77101 and 29 more 2025-06-10 9.8 Critical
CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests.
CVE-2023-6409 1 Schneider-electric 2 Ecostruxure Control Expert, Ecostruxure Process Expert 2025-05-12 7.7 High
CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to a project file protected with application password when opening the file with EcoStruxure Control Expert.