| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| NetSarang Xmanager Enterprise 5.0 Build 1232, Xmanager 5.0 Build 1045, Xshell 5.0 Build 1322, Xftp 5.0 Build 1218, and Xlpd 5.0 Build 1220 contain a malicious nssock2.dll that implements a multi-stage, DNS-based backdoor. The dormant library contacts a C2 DNS server via a specially crafted TXT record for a month‑generated domain. After receiving a decryption key, it then downloads and executes arbitrary code, creates an encrypted virtual file system (VFS) in the registry, and grants the attacker full remote code execution, data exfiltration, and persistence. NetSarang released builds for each product line that remediated the compromise: Xmanager Enterprise Build 1236, Xmanager Build 1049, Xshell Build 1326, Xftp Build 1222, and Xlpd Build 1224. Kaspersky Lab identified an instance of exploitation in the wild in August 2017. |
| A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code. |
| The MCP inspector is a developer tool for testing and debugging MCP servers. Versions of MCP Inspector below 0.14.1 are vulnerable to remote code execution due to lack of authentication between the Inspector client and proxy, allowing unauthenticated requests to launch MCP commands over stdio. Users should immediately upgrade to version 0.14.1 or later to address these vulnerabilities. |
| A vulnerability was identified in Docker Desktop that allows local running Linux containers to access the Docker Engine API via the configured Docker subnet, at 192.168.65.7:2375 by default. This vulnerability occurs with or without Enhanced Container Isolation (ECI) enabled, and with or without the "Expose daemon on tcp://localhost:2375 without TLS" option enabled.
This can lead to execution of a wide range of privileged commands to the engine API, including controlling other containers, creating new ones, managing images etc. In some circumstances (e.g. Docker Desktop for Windows with WSL backend) it also allows mounting the host drive with the same privileges as the user running Docker Desktop. |
| A certificate verification error in wolfSSL when building with the WOLFSSL_SYS_CA_CERTS and WOLFSSL_APPLE_NATIVE_CERT_VALIDATION options results in the wolfSSL
client failing to properly verify the server certificate's domain name,
allowing any certificate issued by a trusted CA to be accepted regardless of the hostname. |
| UNI-NMS-Lite uses hard-coded credentials that could allow an
unauthenticated attacker to gain administrative privileges to all
UNI-NMS managed devices. |
| 2nd Order SQL injection vulnerabilities in ASPECT allow unintended access and manipulation of database repositories if administrator credentials become compromised.This issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| This vulnerability allows the successful attacker to gain unauthorized access to a
configuration web page delivered by the integrated web Server of EIBPORT.
This issue affects EIBPORT V3 KNX: through 3.9.8; EIBPORT V3 KNX GSM: through 3.9.8. |
| pREST (PostgreSQL REST), is an API that delivers an application on top of a Postgres database. SQL injection is possible in versions prior to 2.0.0-rc3. The validation present in versions prior to 2.0.0-rc3 does not provide adequate protection from injection attempts. Version 2.0.0-rc3 contains a patch to mitigate such attempts. |
| A stored XSS vulnerability in No Boss Testimonials component 1.0.0-3.0.0 and 4.0.0-4.0.2 for Joomla was discovered. |
| Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Newtec/iDirect NTC2218, NTC2250, NTC2299 on Linux, PowerPC, ARM allows Local Code Inclusion.This issue affects NTC2218, NTC2250, NTC2299: from 1.0.1.1 through 2.2.6.19.
The `commit_multicast` page used to configure multicasts in the modem's web administration interface uses improperly parses incoming data from the request before passing it to an `eval` statement in a bash script. This allows attackers to inject arbitrary shell commands. |
| ComfyUI-Ace-Nodes is vulnerable to Code Injection. The ACE_ExpressionEval node contains an eval() in its entrypoint function that accepts arbitrary user-controlled data. A user can create a workflow that results in executing arbitrary code on the server. |
| ComfyUI-Impact-Pack is vulnerable to Path Traversal. The issue stems from missing validation of the `image.filename` field in a POST request sent to the `/upload/temp` endpoint added by the extension to the server. This results in writing arbitrary files to the file system which may, under some conditions, result in remote code execution (RCE). |
| The equipment initially can be configured using the manufacturer's application, by Wi-Fi, by the web server or with the manufacturer’s software.
Using the manufacturer's software, the device can be configured via UDP. Analyzing this communication, it has been observed that any aspect of the initial configuration can be changed by means of the device's MAC without the need for authentication. |
| Contec Health CMS8000 Patient Monitor is vulnerable to an out-of-bounds write, which could allow an attacker to send specially formatted UDP requests in order to write arbitrary data. This could result in remote code execution. |
| A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset. |
| Use of Default Cryptographic Key vulnerability in Baxter Welch Allyn Connex Spot Monitor may allow Configuration/Environment Manipulation.This issue affects Welch Allyn Connex Spot Monitor in all versions prior to 1.52. |
| Improper Input validation leads to XSS or Cross-site Scripting vulnerability in OpenText Advanced Authentication. This issue affects Advanced Authentication versions before 6.5. |
| SmartBI V8, V9, and V10 contain an unrestricted file upload vulnerability via the RMIServlet request handling logic. Under certain configurations or usage patterns, attackers can send specially crafted requests that cause the application to perform sensitive operations or execute arbitrary code on the host. The vendor released a fix in July 2023 to address the underlying flaw. VulnCheck has observed this vulnerability being exploited in the wild. |
| XSS Attack in mar.jar, Monitoring Archive Utility (MAR Utility), monitoringconsolecommon.jar in TIBCO Software Inc TIBCO Hawk and TIBCO Operational Intelligence |