| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Huawei Honor 5S smart phones with software the versions before TAG-TL00C01B173 have an authentication bypass vulnerability due to the improper design of some components. An attacker can get a user's smart phone and install malicious apps in the mobile phone, allowing the attacker to reset the password and fingerprint of the phone without authentication. |
| Apache Solr uses a PKI based mechanism to secure inter-node communication when security is enabled. It is possible to create a specially crafted node name that does not exist as part of the cluster and point it to a malicious node. This can trick the nodes in cluster to believe that the malicious node is a member of the cluster. So, if Solr users have enabled BasicAuth authentication mechanism using the BasicAuthPlugin or if the user has implemented a custom Authentication plugin, which does not implement either "HttpClientInterceptorPlugin" or "HttpClientBuilderPlugin", his/her servers are vulnerable to this attack. Users who only use SSL without basic authentication or those who use Kerberos are not affected. |
| An issue was discovered in Sesami Cash Point & Transport Optimizer (CPTO) 6.3.8.6 (#718), allows local attackers to obtain sensitive information and bypass authentication via "Back Button Refresh" attack. |
| Common encryption key appears to be used across all deployed instances of Serv-U FTP Server. Because of this an encrypted value that is exposed to an attacker can be simply recovered to plaintext. |
| A support user exists on the device and appears to be a backdoor for Technical Support staff. The default password for this account is “support” and cannot be changed by a user via any normally accessible means. |
| The web interface of the 1734-AENTR communication module mishandles authentication for HTTP POST requests. A remote, unauthenticated attacker can send a crafted request that may allow for modification of the configuration settings. |
| The Microchip RN4870 module firmware 1.43 (and the Microchip PIC LightBlue Explorer Demo 4.2 DT100112) allows attackers to bypass passkey entry in legacy pairing. |
| There are insufficient warnings when a Fixlet is imported by a user. The warning message currently assumes the owner of the script is the logged in user, with insufficient warnings when attempting to run the script.
|
| NPS before v0.26.10 was discovered to contain an authentication bypass vulnerability via constantly generating and sending the Auth key and Timestamp parameters. |
| A thread security vulnerability exists in the authentication process. Successful exploitation of this vulnerability may affect data integrity, confidentiality, and availability. |
| The sensor privacy module has an authentication vulnerability. Successful exploitation of this vulnerability may cause unavailability of the smartphone's camera and microphone. |
| Some smartphones have authentication-related (including session management) vulnerabilities as the setup wizard is bypassed. Successful exploitation of this vulnerability affects the smartphone availability. |
| Sequi PortBloque S has a improper authentication issues which may allow an attacker to bypass the authentication process and gain user-level access to the device. |
| The web application on Agilia Link+ version 3.0 implements authentication and session management mechanisms exclusively on the client-side and does not protect authentication attributes sufficiently. |
| Fresenius Kabi Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 allows user input to be validated on the client side without authentication by the server. The server should not rely on the correctness of the data because users might not support or block JavaScript or intentionally bypass the client-side checks. An attacker with knowledge of the service user could circumvent the client-side control and login with service privileges. |
| MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 does not perform proper authorization and authentication checks on multiple API routes. An attacker may gain access to these API routes and achieve remote code execution, create a denial-of-service condition, and obtain sensitive information. |
| Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active. |
| All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker can connect to the PLC and read the project without authorization. |
| Navigating to a specific URL with a patient ID number will result in the server generating a PDF of a lab report without authentication and rate limiting. |
| A vulnerability classified as problematic has been found in GE Voluson S8. Affected is the file /uscgi-bin/users.cgi of the Service Browser. The manipulation leads to improper authentication and elevated access possibilities. It is possible to launch the attack on the local host. |