| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The iSherlock developed by Hgiga has an OS Command Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary OS commands and execute them on the server. This vulnerability has already been exploited. Please update immediately. |
| QiAnXin TianQing Management Center versions up to and including 6.7.0.4130 contain a path traversal vulnerability in the rptsvr component that allows unauthenticated attackers to upload files to arbitrary locations on the server. The /rptsvr/upload endpoint fails to sanitize the filename parameter in multipart form-data requests, enabling path traversal. This allows attackers to place executable files in web-accessible directories, potentially leading to remote code execution. Exploitation evidence was first observed by the Shadowserver Foundation on 2024-08-23 UTC. |
| A remote code execution vulnerability exists in Kaltura versions prior to 11.1.0-2 due to unsafe deserialization of user-controlled data within the keditorservices module. An unauthenticated remote attacker can exploit this issue by sending a specially crafted serialized PHP object in the kdata GET parameter to the redirectWidgetCmd endpoint. Successful exploitation leads to execution of arbitrary PHP code in the context of the web server process. |
| SQL injection vulnerability in Infoticketing. This vulnerability allows
an unauthenticated attacker to retrieve, create, update, and delete the
database by sending a POST request using the 'code' parameter in '/components/cart/cartApplyDiscount.php'. |
| A vulnerability has been identified in Mendix LDAP (All versions < V1.1.2). Affected versions of the module are vulnerable to LDAP injection. This could allow an unauthenticated remote attacker to bypass username verification. |
| GeoVision embedded IP devices, confirmed on GV-BX1500 and GV-MFD1501, contain a remote command injection vulnerability via /PictureCatch.cgi that enables an attacker to execute arbitrary commands on the device. The vulnerable models have been declared end-of-life (EOL) by the vendor. VulnCheck has observed this vulnerability being exploited in the wild as of 2025-10-19 08:55:13.141502 UTC. |
| PCL (Plain Craft Launcher) Community Edition is a Minecraft launcher. In PCL CE versions 2.12.0-beta.5 to 2.12.0-beta.9, the login credentials used during the third-party login process are accidentally recorded in the local log file. Although the log file is not automatically uploaded or shared, if the user manually sends the log file, there is a risk of leakage. This is fixed in version 2.12.0-beta.10. |
| Akka.NET is a .NET port of the Akka project from the Scala / Java community. In all versions of Akka.Remote from v1.2.0 to v1.5.51, TLS could be enabled via our `akka.remote.dot-netty.tcp` transport and this would correctly enforce private key validation on the server-side of inbound connections. Akka.Remote, however, never asked the outbound-connecting client to present ITS certificate - therefore it's possible for untrusted parties to connect to a private key'd Akka.NET cluster and begin communicating with it without any certificate. The issue here is that for certificate-based authentication to work properly, ensuring that all members of the Akka.Remote network are secured with the same private key, Akka.Remote needed to implement mutual TLS. This was not the case before Akka.NET v1.5.52. Those who run Akka.NET inside a private network that they fully control or who were never using TLS in the first place are now affected by the bug. However, those who use TLS to secure their networks must upgrade to Akka.NET V1.5.52 or later. One patch forces "fail fast" semantics if TLS is enabled but the private key is missing or invalid. Previous versions would only check that once connection attempts occurred. The second patch, a critical fix, enforces mutual TLS (mTLS) by default, so both parties must be keyed using the same certificate. As a workaround, avoid exposing the application publicly to avoid the vulnerability having a practical impact on one's application. However, upgrading to version 1.5.52 is still recommended by the maintainers. |
| PyVista provides 3D plotting and mesh analysis through an interface for the Visualization Toolkit (VTK). Version 0.46.3 of the PyVista Project is vulnerable to remote code execution via dependency confusion. Two pieces of code use`--extra-index-url`. But when `--extra-index-url` is used, pip always checks for the PyPI index first, and then the external index. One package listed in the code is not published in PyPI. If an attacker publishes a package with higher version in PyPI, the malicious code from the attacker controlled package may be pulled, leading to remote code execution and a supply chain attack. As of time of publication, a patched version is unavailable. |
| scratch-coding-hut.github.io is the website for Coding Hut. In 1.0-beta3 and earlier, the login link can be used to login to any account by changing the username in the username field. |
| serverless-dns is a RethinkDNS resolver that deploys to Cloudflare Workers, Deno Deploy, Fastly, and Fly.io. Versions through abd including 0.1.30 have a vulnerability where the pr.yml GitHub Action interpolates in an unsafe manner untrusted input, specifically the github.event.pull_request.head.repo.clone_url and github.head_ref, to a command in the runner. Due to the action using the pull_request_target trigger it has permissive permissions by default. An unauthorized attacker can exploit this vulnerability to push arbitrary data to the repository. The subsequent impact on the end-user is executing the attackers' code when running serverless-dns. This is fixed in commit c5537dd, and expected to be released in 0.1.31. |
| RISC Zero is a zero-knowledge verifiable general computing platform based on zk-STARKs and the RISC-V microarchitecture. In versions 2.0.2 and below of risc0-zkvm-platform, when the zkVM guest calls sys_read, the host is able to use a crafted response to write to an arbitrary memory location in the guest. This capability can be leveraged to execute arbitrary code within the guest. As sys_read is the mechanism by which input is requested by the guest, all guest programs built with the affected versions are vulnerable. This critically compromises the soundness guarantees of the guest program. Other affected packages include risc0-aggregation versions below 0.9, risc0-zkos-v1compat below 2.1.0, risc0-zkvm versions between 3.0.0-rc.1 and 3.0.1. This issue has been fixed in the following versions: risc0-zkvm-platform 2.1.0, risc0-zkos-v1compat 2.1.0, risc0-aggregation 0.9, and risc0-zkvm 2.3.2 and 3.0.3. |
| The affected product is vulnerable to a cross-site scripting attack which may allow an attacker to bypass authentication and takeover admin accounts. |
| The embedded web server lacks authentication and access controls, allowing unrestricted remote access. This could lead to configuration changes, operational disruption, or arbitrary code execution depending on the environment and exposed functionality. |
| When uploading organism or sequence data via the web interface,
GMOD Apollo
will unzip and inspect the files and will not check for path
traversal in supported archive types. |
| KUNBUS PiCtory versions 2.5.0 through 2.11.1 have an authentication bypass vulnerability where a remote attacker can bypass authentication to get access due to a path traversal. |
| The "system" function receives untrusted input from the user. If the "EnableJSCaching" option is enabled, it is possible to execute arbitrary code provided as the "Module" parameter. |
| An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a "mmBackup" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data.
This issue affects Asseco mMedica in versions before 11.9.5. |
| An Use of Hard-coded Credentials vulnerability has been identified in Moxa’s network security appliances and routers. The system employs a hard-coded secret key to sign JSON Web Tokens (JWT) used for authentication. This insecure implementation allows an unauthenticated attacker to forge valid tokens, thereby bypassing authentication controls and impersonating any user. Exploitation of this vulnerability can result in complete system compromise, enabling unauthorized access, data theft, and full administrative control over the affected device. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems. |
| An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A critical authorization flaw in the API allows an authenticated, low-privileged user to create a new administrator account, including accounts with usernames identical to existing users. In certain scenarios, this vulnerability could allow an attacker to gain full administrative control over the affected device, leading to potential account impersonation. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems. |