| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue was discovered in the node-serialize package 0.0.4 for Node.js. Untrusted data passed into the unserialize() function can be exploited to achieve arbitrary code execution by passing a JavaScript Object with an Immediately Invoked Function Expression (IIFE). |
| The camel-hessian component in Apache Camel 2.x before 2.19.4 and 2.20.x before 2.20.1 is vulnerable to Java object de-serialisation vulnerability. De-serializing untrusted data can lead to security flaws. |
| CrushFTP 8.x before 8.2.0 has a serialization vulnerability. |
| PHPMemcachedAdmin 1.2.2 and earlier allows remote attackers to execute arbitrary PHP code via vectors related "serialized data and the last part of the concatenated filename," which creates a file in webroot. |
| Deserialization vulnerability in synophoto_csPhotoMisc.php in Synology Photo Station before 6.7.3-3432 and 6.3-2967 allows remote attackers to gain administrator privileges via a crafted serialized payload. |
| Deserialization of Untrusted Data in jeecgFormDemoController in JEECG 4.0 and earlier allows attackers to run arbitrary code via crafted POST request. |
| The SolarWinds Security Event Manager was susceptible to Remote Code Execution Vulnerability. This vulnerability allows an unauthenticated user to abuse SolarWinds’ service, resulting in remote code execution. |
| The system tool has inconsistent serialization and deserialization. Successful exploitation of this vulnerability will cause unauthorized startup of components. |
| Rockwell Automation Connected Components Workbench v12.00.00 and prior does not limit the objects that can be deserialized. This vulnerability allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in remote code execution. This vulnerability requires user interaction to be successfully exploited. |
| Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited |
| The affected Cognex product, the In-Sight OPC Server versions v5.7.4 (96) and prior, deserializes untrusted data, which could allow a remote attacker access to system level permission commands and local privilege escalation. |
| Rockwell Automation ISaGRAF Workbench software versions 6.0 through 6.6.9 are affected by a Deserialization of Untrusted Data vulnerability. ISaGRAF Workbench does not limit the objects that can be deserialized. This vulnerability allows attackers to craft a malicious serialized object that, if opened by a local user in ISaGRAF Workbench, may result in remote code execution. This vulnerability requires user interaction to be successfully exploited. |
|
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote code execution.
|
| MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 has a deserialization function that does not validate or check the data, allowing arbitrary classes to be created. |
| Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier components contain .NET remoting endpoints that deserialize untrusted data without sufficiently verifying that the resulting data will be valid. This vulnerability may allow a remote, unauthenticated attacker to gain full access to the FactoryTalk AssetCentre main server and all agent machines. |
| A deserialization vulnerability exists in how the AosService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier verifies serialized data. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in FactoryTalk AssetCentre. |
| A deserialization vulnerability exists in how the ArchiveService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier verifies serialized data. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in FactoryTalk AssetCentre. |
| A deserialization vulnerability exists in how the LogService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier verifies serialized data. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in FactoryTalk AssetCentre. |
| The affected products are vulnerable of untrusted data due to deserialization without prior authorization/authentication, which may allow an attacker to remotely execute arbitrary code. |
|
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.
|