Export limit exceeded: 348772 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 79904 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (79904 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2020-7586 | 1 Siemens | 4 Simatic Pcs 7, Simatic Process Device Manager, Simatic Step 7 and 1 more | 2024-11-21 | 7.8 High |
| A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A buffer overflow vulnerability could allow a local attacker to cause a Denial-of-Service situation. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information. | ||||
| CVE-2020-7585 | 1 Siemens | 4 Simatic Pcs 7, Simatic Process Device Manager, Simatic Step 7 and 1 more | 2024-11-21 | 7.8 High |
| A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information. | ||||
| CVE-2020-7584 | 1 Siemens | 4 Simatic S7-200 Smart Sr Cpu, Simatic S7-200 Smart Sr Cpu Firmware, Simatic S7-200 Smart St Cpu and 1 more | 2024-11-21 | 7.5 High |
| A vulnerability has been identified in SIMATIC S7-200 SMART CPU family (All versions >= V2.2 < V2.5.1). Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service situation. | ||||
| CVE-2020-7583 | 1 Siemens | 1 Automation License Manager | 2024-11-21 | 7.8 High |
| A vulnerability has been identified in Automation License Manager 5 (All versions), Automation License Manager 6 (All versions < V6.0.8). The application does not properly validate the users' privileges when executing some operations, which could allow a user with low permissions to arbitrary modify files that should be protected against writing. | ||||
| CVE-2020-7578 | 1 Siemens | 1 Opcenter Execution Core | 2024-11-21 | 8.1 High |
| A vulnerability has been identified in Camstar Enterprise Platform (All versions), Opcenter Execution Core (All versions < V8.2). Authenticated users could have access to resources they normally would not have. This vulnerability could allow an attacker to view internal information and perform unauthorized changes. | ||||
| CVE-2020-7577 | 1 Siemens | 1 Opcenter Execution Core | 2024-11-21 | 8.1 High |
| A vulnerability has been identified in Camstar Enterprise Platform (All versions), Opcenter Execution Core (All versions < V8.2). Through the use of several vulnerable fields of the application, an authenticated user could perform an SQL Injection attack by passing a modified SQL query downstream to the back-end server. The exploit of this vulnerability could be used to read, and potentially modify application data to which the user has access to. | ||||
| CVE-2020-7572 | 1 Schneider-electric | 1 Webreports | 2024-11-21 | 8.8 High |
| A CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to inject arbitrary XML code and obtain disclosure of confidential data, denial of service, server side request forgery due to improper configuration of the XML parser. | ||||
| CVE-2020-7569 | 1 Schneider-electric | 1 Webreports | 2024-11-21 | 8.8 High |
| A CWE-434 Unrestricted Upload of File with Dangerous Type vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to upload arbitrary files due to incorrect verification of user supplied files and achieve remote code execution. | ||||
| CVE-2020-7566 | 1 Schneider-electric | 2 Modicon M221, Modicon M221 Firmware | 2024-11-21 | 7.3 High |
| A CWE-334: Small Space of Random Values vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption keys when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller. | ||||
| CVE-2020-7565 | 1 Schneider-electric | 2 Modicon M221, Modicon M221 Firmware | 2024-11-21 | 7.3 High |
| A CWE-326: Inadequate Encryption Strength vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption key when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller. | ||||
| CVE-2020-7564 | 1 Schneider-electric | 40 Modicon M340 Bmx Noc 0401, Modicon M340 Bmx Noc 0401 Firmware, Modicon M340 Bmx Noe 0100 and 37 more | 2024-11-21 | 8.8 High |
| A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause write access and the execution of commands when uploading a specially crafted file on the controller over FTP. | ||||
| CVE-2020-7563 | 1 Schneider-electric | 40 Modicon M340 Bmx Noc 0401, Modicon M340 Bmx Noc 0401 Firmware, Modicon M340 Bmx Noe 0100 and 37 more | 2024-11-21 | 8.8 High |
| A CWE-787: Out-of-bounds Write vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause corruption of data, a crash, or code execution when uploading a specially crafted file on the controller over FTP. | ||||
| CVE-2020-7562 | 1 Schneider-electric | 40 Modicon M340 Bmx Noc 0401, Modicon M340 Bmx Noc 0401 Firmware, Modicon M340 Bmx Noe 0100 and 37 more | 2024-11-21 | 8.1 High |
| A CWE-125: Out-of-Bounds Read vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause a segmentation fault or a buffer overflow when uploading a specially crafted file on the controller over FTP. | ||||
| CVE-2020-7560 | 1 Schneider-electric | 2 Ecostruxure Control Expert, Unity Pro | 2024-11-21 | 8.6 High |
| A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure™ Control Expert software. | ||||
| CVE-2020-7559 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2024-11-21 | 7.5 High |
| A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus. | ||||
| CVE-2020-7558 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | 7.8 High |
| A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||
| CVE-2020-7557 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | 7.8 High |
| A CWE-125 Out-of-bounds Read vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||
| CVE-2020-7556 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | 7.8 High |
| A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||
| CVE-2020-7555 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | 7.8 High |
| A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||
| CVE-2020-7554 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | 7.8 High |
| A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||