Export limit exceeded: 347766 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Export limit exceeded: 347766 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (347766 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-43803 1 Redhat 1 Openshift 2026-04-15 4.9 Medium
The Bare Metal Operator (BMO) implements a Kubernetes API for managing bare metal hosts in Metal3. The `BareMetalHost` (BMH) CRD allows the `userData`, `metaData`, and `networkData` for the provisioned host to be specified as links to Kubernetes Secrets. There are fields for both the `Name` and `Namespace` of the Secret, meaning that versions of the baremetal-operator prior to 0.8.0, 0.6.2, and 0.5.2 will read a `Secret` from any namespace. A user with access to create or edit a `BareMetalHost` can thus exfiltrate a `Secret` from another namespace by using it as e.g. the `userData` for provisioning some host (note that this need not be a real host, it could be a VM somewhere). BMO will only read a key with the name `value` (or `userData`, `metaData`, or `networkData`), so that limits the exposure somewhat. `value` is probably a pretty common key though. Secrets used by _other_ `BareMetalHost`s in different namespaces are always vulnerable. It is probably relatively unusual for anyone other than cluster administrators to have RBAC access to create/edit a `BareMetalHost`. This vulnerability is only meaningful, if the cluster has users other than administrators and users' privileges are limited to their respective namespaces. The patch prevents BMO from accepting links to Secrets from other namespaces as BMH input. Any BMH configuration is only read from the same namespace only. The problem is patched in BMO releases v0.7.0, v0.6.2 and v0.5.2 and users should upgrade to those versions. Prior upgrading, duplicate the BMC Secrets to the namespace where the corresponding BMH is. After upgrade, remove the old Secrets. As a workaround, an operator can configure BMO RBAC to be namespace scoped for Secrets, instead of cluster scoped, to prevent BMO from accessing Secrets from other namespaces.
CVE-2025-11772 1 Synaptics 1 Fingerprint Driver 2026-04-15 6.6 Medium
A carefully crafted DLL, copied to C:\ProgramData\Synaptics folder, allows a local user to execute arbitrary code with elevated privileges during driver installation.
CVE-2024-43701 1 Imaginationtech 1 Graphics Ddk 2026-04-15 7.8 High
Software installed and run as a non-privileged user may conduct GPU system calls to read and write freed physical memory from the GPU.
CVE-2024-43659 2026-04-15 7.2 High
After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43657 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43649 2026-04-15 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
CVE-2024-43648 2026-04-15 8.8 High
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).  A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-4363 2026-04-15 6.4 Medium
The Visual Portfolio, Photo Gallery & Post Grid plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the ‘title_tag’ parameter in all versions up to, and including, 3.3.2 due to insufficient input sanitization and output escaping. This makes it possible for authenticated attackers, with author-level access and above, to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page.
CVE-2013-10062 1 Linksys 1 E1500 2026-04-15 N/A
A directory traversal vulnerability exists in Linksys router's web interface (tested on the E1500 model firmware versions 1.0.00, 1.0.04, and 1.0.05), specifically in the /apply.cgi endpoint. Authenticated attackers can exploit the next_page POST parameter to access arbitrary files outside the intended web root by injecting traversal sequences. This allows exposure of sensitive system files and configuration data.
CVE-2025-10571 1 Abb 1 Ability Edgenius 2026-04-15 9.6 Critical
Authentication Bypass Using an Alternate Path or Channel vulnerability in ABB ABB Ability Edgenius.This issue affects ABB Ability Edgenius: 3.2.0.0, 3.2.1.1.
CVE-2025-11676 1 Tp-link 3 Tl-wr940n, Tl-wr940n V6, Wr940n 2026-04-15 N/A
Improper input validation vulnerability in TP-Link System Inc. TL-WR940N V6 (UPnP modules), which allows unauthenticated adjacent attackers to perform DoS attack. This issue affects TL-WR940N V6 <= Build 220801.
CVE-2024-43446 2026-04-15 3.5 Low
An improper privilege management vulnerability in OTRS Generic Interface module allows change of the Ticket status even if the user only has ro permissions. This issue affects: * OTRS 7.0.X * OTRS 8.0.X * OTRS 2023.X * OTRS 2024.X * ((OTRS)) Community Edition: 6.0.x Products based on the ((OTRS)) Community Edition also very likely to be affected
CVE-2024-43445 2026-04-15 5.4 Medium
A vulnerability exists in OTRS and ((OTRS Community Edition)) that fail to set the HTTP response header X-Content-Type-Options to nosniff. An attacker could exploit this vulnerability by uploading or inserting content that would be treated as a different MIME type than intended. This issue affects: * OTRS 7.0.X * OTRS 8.0.X * OTRS 2023.X * OTRS 2024.X * ((OTRS)) Community Edition: 6.0.x Products based on the ((OTRS)) Community Edition also very likely to be affected
CVE-2024-43444 1 Otrs 1 Otrs 2026-04-15 8.2 High
Passwords of agents and customers are displayed in plain text in the OTRS admin log module if certain configurations regarding the authentication sources match and debugging for the authentication backend has been enabled. This issue affects: * OTRS from 7.0.X through 7.0.50 * OTRS 8.0.X * OTRS 2023.X * OTRS from 2024.X through 2024.5.X * ((OTRS)) Community Edition: 6.0.x Products based on the ((OTRS)) Community Edition also very likely to be affected
CVE-2024-43443 2026-04-15 4.9 Medium
Improper Neutralization of Input done by an attacker with admin privileges ('Cross-site Scripting') in Process Management modules of OTRS and ((OTRS)) Community Edition allows Cross-Site Scripting (XSS) within the Process Management targeting other admins. This issue affects: * OTRS from 7.0.X through 7.0.50 * OTRS 8.0.X * OTRS 2023.X * OTRS from 2024.X through 2024.5.X * ((OTRS)) Community Edition: 6.0.x Products based on the ((OTRS)) Community Edition also very likely to be affected
CVE-2024-48924 1 Messagepack 1 Messagepack-csharp 2026-04-15 N/A
### Impact When this library is used to deserialize messagepack data from an untrusted source, there is a risk of a denial of service attack by an attacker that sends data contrived to produce hash collisions, leading to large CPU consumption disproportionate to the size of the data being deserialized. This is similar to [a prior advisory](https://github.com/MessagePack-CSharp/MessagePack-CSharp/security/advisories/GHSA-7q36-4xx7-xcxf), which provided an inadequate fix for the hash collision part of the vulnerability. ### Patches The following steps are required to mitigate this risk. 1. Upgrade to a version of the library where a fix is available. 1. Review the steps in [this previous advisory](https://github.com/MessagePack-CSharp/MessagePack-CSharp/security/advisories/GHSA-7q36-4xx7-xcxf) to ensure you have your application configured for untrusted data. ### Workarounds If upgrading MessagePack to a patched version is not an option for you, you may apply a manual workaround as follows: 1. Declare a class that derives from `MessagePackSecurity`. 2. Override the `GetHashCollisionResistantEqualityComparer<T>` method to provide a collision-resistant hash function of your own and avoid calling `base.GetHashCollisionResistantEqualityComparer<T>()`. 3. Configure a `MessagePackSerializerOptions` with an instance of your derived type by calling `WithSecurity` on an existing options object. 4. Use your custom options object for all deserialization operations. This may be by setting the `MessagePackSerializer.DefaultOptions` static property, if you call methods that rely on this default property, and/or by passing in the options object explicitly to any `Deserialize` method. ### References - Learn more about best security practices when reading untrusted data with [MessagePack 1.x](https://github.com/MessagePack-CSharp/MessagePack-CSharp/tree/v1.x#security) or [MessagePack 2.x](https://github.com/MessagePack-CSharp/MessagePack-CSharp#security). - The .NET team's [discussion on hash collision vulnerabilities of their `HashCode` struct](https://github.com/GrabYourPitchforks/runtime/blob/threat_models/docs/design/security/System.HashCode.md). ### For more information If you have any questions or comments about this advisory: * [Start a public discussion](https://github.com/MessagePack-CSharp/MessagePack-CSharp/discussions) * [Email us privately](mailto:andrewarnott@live.com)